Characterization of grey water in Kyebando, Kisalosalo and determination of the design criteria for greywater systems treating water for irrigation
Abstract
In many urban and peri-urban communities of low and medium income countries, grey water discharge is of increasing concern as population in these areas continues growing, consequently bringing about an increase in quantities of grey water generated.
The main objective of this study was to characterize the grey water in Kyebando, Kisalosalo Zone (Kampala) and design a method of treatment so that it can be upgraded to a safe resource for irrigation
Literature review, questionnaires and observations among other methods were used for data collection. Based on our measurements, the amount of grey water generated in Kyebando is on average 65L/household/day. Analysis was carried out on grey water samples from the area of study to establish the current grey water characteristics. The characteristics of grey water in Kyebando are (on average) 483mg/L, 888mg/L, 11mg/L, 35.9mg/L, 7.9mg/L,5845 cfu/100mL 346mg/L, 6.6 and 459μS/cm for BOD5, COD, NH4-N, TP, Ortho P, faecal coliforms, TSS, pH and EC respectively. These parameters suggest that grey water should be treated before using it at household level.
To develop a design criterion, a laboratory scale model treatment unit was set up and its performance was evaluated. A hydraulic loading rate (HLR) of 60 L m-2d-1 and an organic loading rate (OLR) of 70 g BOD m-2d-1 were implemented on a multi-media filter of gravel, charcoal, geotextile and mulch (charcoal being the predominant layer) operated as a batched type system, with a 24 hour retention time. The system was operated for four weeks, during which it showed remarkable removal efficiencies of 76% and 73% after 24hours for COD and BOD, respectively and 73.1% for feacal coliforms (FC). The removal efficiencies at 24 hours, of feacal Coliforms (FC), Total Phosphorous (Tot-P), and Total Suspended Solids (TSS) were 73.3%, 59.5% and 73.7% respectively. A filter system with a surface area of 0.76m2 was recommended for the adequate treatment of household grey water. It treated water to meet the required standards for Irrigation.
Collections
Related items
Showing items related by title, author, creator and subject.
-
Assessment of customer satisfaction with piped water supply services in Uganda : a case of Nakifuma Town in Mukono District
Hashakimana, Godfrey (Makerere University, 2022)There has been an increasing need to assess the level of customer satisfaction with piped water supply systems in Uganda. This would position the sector in ensuring that everyone has access to piped water supply in all the ... -
An investigation of reliability of the water source and cost-effective chemical use at Masaka Water Treatment Works
Isagara, John Paul (Makerere University, 2012-10)The challenge of providing improved and adequate water services is substantial and this study sought to determine whether the NWSC Masaka Area’s current water source is sufficient to ensure adequate water supply to meet ... -
Assessment of level at which safe water chain is interrupted and associated factors in Rukungiri District
Mugwanya, Edward (Makerere University, 2009-05)Introduction: Contaminated drinking water is a risk to diseases in developing and developed countries. A water quality survey done in two sub-counties in Rukungiri found a higher level of coliforms in the water at household ...