dc.contributor.advisor | Mugasa, Mack Claire | |
dc.contributor.advisor | Adriko, John | |
dc.contributor.author | Driciru, Patricia | |
dc.date.accessioned | 2021-03-23T08:17:10Z | |
dc.date.available | 2021-03-23T08:17:10Z | |
dc.date.issued | 2021-03 | |
dc.identifier.citation | Driciru, P. (2021). Optimization and evaluation of loop-mediated isothermal amplification (LAMP) system for detection of Pseudocercospora angolensis in citrus cinensis (Unpublished master’s dissertation). Makerere University, Kampala, Uganda | en_US |
dc.identifier.uri | http://hdl.handle.net/10570/8240 | |
dc.description | A dissertation submitted to the Directorate of Research and Graduate Training in partial fulfillment for the award of Master of Science in Molecular Biology and Biotechnology Degree of Makerere University. | en_US |
dc.description.abstract | Pseudocercospora angolensis causes Pseudocercospora leaf and fruit spot disease in citrus which can result in up to 100% yield loss. Early diagnosis of this disease is vital for effective control. This study aimed at optimizing and evaluating a loop-mediated amplification (LAMP) system for detecting P. angolensis in sweet oranges using microscopy as a gold standard. The analytical specificity and sensitivity of PCR and LAMP were assessed using twelve (12) non-target species and serial dilutions of P. angolensis DNA respectively. The diagnostic accuracies of the two assays were evaluated using 150 diseased and 50 non-diseased sweet orange leaf samples. The analytical sensitivity and detection time of LAMP were 10-4 ng/µl and 40 minutes respectively. The analytical sensitivity of PCR was 10 ng/µl and it was specific to P. angolensis whereas three relatives of P. angolensis were detectable by LAMP. The diagnostic sensitivities of LAMP (93%) and microscopy (100%) were not significantly different (X2 = 8.38, P = 0.0038) unlike the diagnostic specificities (90%) and (100%), respectively (X2 = 3.37, P = 0.066). Microscopy was significantly more sensitive than PCR (32.6%) (X2 = 149.26, P < 2.2e-16) and equally specific as PCR (P=NA). The positive predictive values of PCR and LAMP were 100% and 96.5% respectively whereas the negative predictive values were 33.1% and 81.8% respectively. The high positive and negative predictive values of LAMP make it a more suitable assay for screening sweet orange samples for P. angolensis than PCR. | en_US |
dc.description.sponsorship | KOPIA-UGANDA | en_US |
dc.language.iso | en | en_US |
dc.publisher | Makerere University | en_US |
dc.subject | LAMP | en_US |
dc.subject | PCR | en_US |
dc.subject | Pseudocercospora angolensis | en_US |
dc.title | Optimization and evaluation of loop-mediated isothermal amplification (LAMP) system for detection of Pseudocercospora angolensis in citrus cinensis | en_US |
dc.type | Thesis | en_US |